Product Overview
The SAME TECHNOLOGY SP-16 Series Differential Pressure & Communication Type Digital Pressure Switch is engineered for accurate micro-pressure monitoring and networked industrial automation. Combining a clear dual-color 5-digit 7-segment LED display (max. 1 Pa resolution) with ±0.2% F.S. repeatability and ±2% F.S. display accuracy, the SP-16 delivers stable small-range differential pressure control. It integrates an RS485 MODBUS communication interface while retaining 1-channel switch output (NPN or PNP), making it well suited for air filter clogging monitoring, pipeline leakage testing, and space-saving multi-unit panel installations.
Product Highlights
5-Digit Display & 1 Pa Resolution
Dual-color 5-digit 7-segment display provides up to 1 Pa maximum resolution and ±2% F.S. display accuracy for clear real-time pressure reading.
±0.2% F.S. Repeatability
High repeatability ensures consistent switching thresholds and dependable control in low-pressure and micro-differential pneumatic lines.
MODBUS RS485 + 1-Ch Switch
Supports industrial RS485 MODBUS communication for PLC/SCADA data acquisition while retaining 1 independent NPN or PNP switch output.
Selection Method & Model Specifications
Model Code Example: SP - 16 - CC - 030 - MM (① Product Series – ② Air Pressure Input Range – ③ Signal Output Type – ④ Air Pressure Fitting Type)
| Code |
Item |
Specification / Options |
| ① |
Product Series |
16: Differential Pressure Communication Type |
| ② |
Air Pressure Input Range |
CA: -500~500.0Pa | CB: -1000.0~1000.0Pa | CC: -2.000~2.000kPa (Not available temporarily) CD: -5.000~5.000kPa | CE: -10.000~10.000kPa CF: -40.000kPa~40.000kPa | CG: -100.00kPa~100.00kPa |
| ③ |
Signal Output Type |
030: 1-channel NPN + 1 set of RS485 communication 031: 1-channel PNP + 1 set of RS485 communication |
| ④ |
Air Pressure Fitting Type |
MM: Dual air nozzle fitting, female M5 thread |
Typical Industrial Applications
- • Air Filter Clogging Detection: Connects the high-pressure and low-pressure channels across a compressed air filter to monitor pressure drop and trigger timely filter replacement alerts.
- • Pipeline Leakage Detection: Compares the test object against a reference standard via solenoid valves to detect minute differential pressure changes caused by air leaks.
- • Pipeline Filter Air Monitoring: Continuously tracks differential pressure across duct and pipeline filter elements to maintain stable airflow and equipment efficiency.
Circuit Wiring & Pin Definitions
The SP-16 Series operates on a DC 12–24V power supply and is available in two output configurations: SP-16□030□ (1-channel NPN + 1 set of RS485) and SP-16□031□ (1-channel PNP + 1 set of RS485). Refer to the 5-pin cable definition below:
| Pin No |
Wire Color |
Signal Name |
Function Definition |
| 1 |
Brown |
DC+ |
Positive Power Supply (DC 12–24V) |
| 2 |
Black |
OUT1 |
Switch Output 1 (NPN for 030 / PNP for 031) |
| 3 |
White |
485A |
RS485 Communication A (MODBUS) |
| 4 |
Orange |
485B |
RS485 Communication B (MODBUS) |
| 5 |
Blue |
DC− |
Negative Power Supply (0V) |
Wiring Precaution: For communication-type wiring, always connect the RS485 communication cables (485A / 485B) first, then connect the DC power cables (DC+ / DC−) to prevent short circuits and potential product damage.
Mounting Methods & Optional Accessories
Accessory Models (Optional, Separate Order Required):
- 1. L-type metal mounting bracket: XP-BT-04
- 2. Z-type metal mounting bracket: XP-BT-05
- 3. Panel mounting bracket: XP-PA-01
- 4. Barbed fitting, internal M5 fitting for φ4 air tube: XP-BT4-M5
- 5. Barbed fitting, internal M5 fitting for φ6 air tube: XP-BT6-M5
- 6. Quick screw fitting, internal M5 fitting for φ4 air tube: XP-KN4-M5
- 7. Quick screw fitting, internal M5 fitting for φ6 air tube: XP-KN6-M5
- • Compact Panel Mounting & Protective Cover: Supports tight side-by-side or vertical multi-unit panel arrays to save cabinet space, with an optional snap-on front protective cover to prevent accidental button operation.
Frequently Asked Questions (FAQ)
Q: What is the difference between SP-16 030 and SP-16 031 models?
A: Both models include 1 set of RS485 MODBUS communication and operate on DC 12–24V. The difference lies in the retained switch output channel (OUT1): SP-16 030 provides a 1-channel NPN output, while SP-16 031 provides a 1-channel PNP output.
Q: What resolution and repeatability can the SP-16 Series achieve?
A: The SP-16 Series features a 5-digit 7-segment LED display with a maximum resolution of 1 Pa, display accuracy of ±2% F.S., and repeatability of ±0.2% F.S., making it suitable for precise small-range differential pressure monitoring.
Q: What wiring sequence should be followed when connecting RS485 communication?
A: Always connect the communication wires (White 485A and Orange 485B) first before connecting the DC 12–24V power wires (Brown DC+ and Blue DC−) to avoid short circuits and damage to the internal communication circuit.
Q: Are the XP-BT-04 and XP-BT-05 mounting brackets included with the switch?
A: No, both the L-type metal mounting bracket (XP-BT-04) and the Z-type metal mounting bracket (XP-BT-05) are optional accessories and must be ordered separately based on your installation layout.