product info

Intelligent Leak Detection Control Module(SLD-30 Series)

SLD-30 Series Intelligent Leak Detection Control Module is an advanced, ultra-low-cost alternative to bulky, traditional leak testing machinery. Designed for precision and industrial efficiency, this integrated controller delivers real-time pressure monitoring, precise leakage measurement, and automatic pass/fail evaluation directly to your automated assembly line.

Whether you are conducting rigorous blockage, seal, or leakage tests, the SLD-30 provides a comprehensive and flexible solution to meet multi-scenario needs. Equipped with a highly visible color LCD display, intelligent self-diagnosis algorithms, and direct solenoid valve control capabilities, it significantly saves time, effort, and operational costs while streamlining quality inspection across diverse sectors—from consumer electronics and pharmaceutical packaging to automotive manufacturing.

  • Air Pressure Input Range :

    L: -10~10kPa (Small-range Model) | P: -0.1~1.0MPa | C:-101.3~101.3kPa
  • Air Pressure fitting Type :

    H6: 6mm air tube quick-connect metal fitting | H4: 4mm air tube quick-connect metal fitting

Product Overview

The SLD-30 Series Intelligent Leak Detection Control Module is engineered to provide an optimal, multi-scenario leak detection solution. Delivering exclusive leak detection capabilities, it significantly saves time, effort, and operational costs. Applicable for blockage, seal, and leakage tests, this device features integrated control functions with self-diagnosis and learning capabilities, acting as a highly precise, ultra-low-cost alternative to bulky testing machinery.

Product Highlights

Flexible Testing Modes

Compact and fully featured with Automatic/Manual modes, target setting, tolerance setting, and specific leak test time configurations.

Integrated Control & Safety

Equipped with internal self-diagnosis, integrated valve control, and automatic pressure relief in the event of an error.

Color LCD Display

Provides real-time pressure display and precise leakage measurement with automatic pass/fail evaluation for intuitive viewing.

SLD-30 Leak Detection Modes
SLD-30 Leak Detection ModesSLD-30 Real-Time Display 

Model Selection & Technical Framework

Designed for versatility across testing stations, the SLD-30 series offers a structured parameter configuration for diverse industrial needs:

Series Designation 30: Standard Leak Detection Control Type.
Air Pressure Input Range C: -101.3~101.3kPa | L: -10.000~10.000kPa (Small-range Model) | P: -0.1~1.0MPa.
Air Pressure Fitting Type H6: 6mm air tube quick-connect metal fitting | H4: 4mm air tube quick-connect metal fitting.
Multiple Interfaces Comprehensive Functions: Output features COMO, OK, NG, BUSY, V+, V-, D+, D- for full integration.
 

Mounting Methods & Circuit Connections

Connection Guidelines:

  • • Input Wiring: The input features a bidirectional optocoupler with no polarity requirement; it conducts regardless of wiring orientation (24V, 0V, START, STOP).
  • • Output Wiring: The connected external device must be powered separately. The module functions solely as a high-precision switch to control external equipment.
SLD-30 Circuit Wiring Diagram
SLD-30 Multiple Interfaces

Comprehensive Application Scenarios

Equipped with low-leakage pneumatic fittings, the SLD-30 thrives in strict quality control environments:

Consumer Electronics Waterproof performance testing of smart devices, smart wearables, and home appliances.
Security & Comm. Air tightness testing of outdoor surveillance security, communication facilities, and monitoring equipment.
Industrial Pipelines Continuous leakage monitoring for valve testing, industrial pipeline systems, and refrigeration equipment.
Auto & Packaging Seal testing of new energy components, automotive parts, food, and pharmaceutical packaging.
SLD-30 Application Scenarios

Frequently Asked Questions (FAQ)

Q: Can the SLD-30 control external testing valves directly?

A: Yes, it features integrated valve control. It acts as a switch to manage external equipment, but the connected devices must be powered separately.

Q: Are there specific polarity requirements for wiring the input?

A: No. The input utilizes a bidirectional optocoupler with no polarity requirement, conducting regardless of the wiring orientation.

Q: What testing modes are supported?

A: The module supports both Automatic and Manual modes, allowing users to configure target values, tolerance, excess air intake, and leak test times flexibly.

 

Company Advantages & Factory Strength

  Factory Facility Production Line Quality Control
Company Certifications Company Awards Global Delivery
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.